Technical Data and Questions > Corrosive Test Data From NASA (Test Bed & KSC Report)

Corrosive Test Data From NASA (Test Bed & KSC Report)

The Atmospheric Exposure Site (Kennedy Space Center, FL.) was established in the 1960s and has been cited as the most corrosive atmospheric corrosion test site in the United States. It is located at latitude 28.7ÿN, longitude 80.6ÿW, and approximately 100 feet from the high tide line. Over the years thousands of coated test panels, stress corrosion cracking specimens, and commercially produced components have been evaluated in the high salt, high humidity, high UV Florida seacoast environment.

Corrosion Rates of Carbon Steel Calibrating Specimens at Various Locations*

Location or Region Type of Environment um/year Corrosion Rate (a) Mils/Year
Esquimalt, Vancouver Island, BC, Canada Rural Marine 13 0.5
Pittsburg, Pa Industrial 30 1.2
Cleveland, OH Industrial 38 1.5
Limon bay, Panama, CZ Tropical Marine 61 2.4
East Chicago,IL Industrial 84 3.3
Brazos River, TX Industrial Marine 94 3.7
Daytona Beach, Fl Marine 295 11.6
Pont Reyes,CA Marine 500 19.7
Kure Beach, NC Marine 533 21.0
Galeta Point Beach,Panama, CZ Marine 686 27.0
Kennedy Space Center, Fl Marine 1070 42.0

 

a) Two-year average * Data extracted from: S. Coburn, Atmospheric Corrosion, in Metals Handbook, 9th ed, Vol. 1, Properties and Selection, Carbon Steels, American Society for Metals, Metals Park, Ohio, 1978, p. 720.

 

The site has approximately 600 feet of front row exposure for atmospheric corrosion specimens. Many types of test samples can be accommodated, including standard size test coupons (4Ó x 6Ó), stress corrosion cracking specimens, and full-scale test articles. These experiments can be performed in either a boldly exposed or sheltered configuration. Both power and data connections are available within the site to power tests articles and record on board data instrumentation outputs.